Home Feedback Search Sell your products Meet us News


SMART BCA Protein Assay Kit

 
Up

 

Home
Up

 

GENTAUR

+32 1658 9045

or

0032 (0)16 41 44 07

+32 1650 9045

info@gentaur.com

Av. de l' Armée 68

B-1040 Brussels

BELGIUM

France

tel 01 43 25 01 50

fax01 43 25 01 60

9, rue Lagrange

75005 Paris

Italia

tel 02 36 00 65 93

fax 02 36 00 65 94

20135 Milano

Deutschland

tel +32 1658 9045

fax +32 1650 9045

Polska

Tel 00 48 51 760 77 08

Fax 00 32 16 50 90 45

Ulica Ogarna 15/19 B m2

80-826 Gdansk

日本

tel +81 78 386 0860

fax +81 78 306 0296

Minaatojimaminami-manchi

Chuo-ku, Kobe

065-0047

Österreich
+43720880899

Canada Montreal
+15149077481

Česká republika Praha
+420246019719

Danmark
+4569918806

Finland Helsset
+358942419041

Ελλάς Αθήνα
+302111768494

Magyarország Budapest
+3619980547

Ireland Dublin
+35316526556

Luxembourg
+35220880274

Nederland
+31208080893

Norge Oslo
+4721031366

Polska Warszawa
+48223988221

Sverige Stockholm
+46852503438

Schweiz Züri
+41435006251

US New York
+17185132983

Other Countries
0032 (0)16 41 44 07


 

 

 

 

 

Clonagen

Gentaur

Genprice

Bioxys

Labprice

 

SMARTTM BCA Protein Assay Kit (for Standard assay)
Cat. No Size
21071 250 T
 

 
The smartTM BCA protein assay kit(for Standard Assay) is a detergent-compatible formulation based on bicinchoninic acid(BCA) for the colorimetric detection and quantitation of total protein. The purple-colored reaction product of this assay is formed by the chelation of two molecules of BCA with one cuprous ion. This water-soluble complex exhibits a strong absorbance at 562 nm that is nearly linear with increasing protein concentrations over a broad working range. (20-2,000 ug/ml)
The macromolecular structure of protein, the number of peptide bonds and the presence of four particular amino acids(cystein, cystine, tryptophan and tyrosine)are reported to be responsible for color formation with BCA. Studies with di-, tri- and tetrapeptides suggest that the extent of color formation caused by more than the mere sum of individual colorproducing functional groups. Accordingly, protein concentrations generally are determined and reported with reference to standards of a common protein such as bovine serum albumin (BSA). A series of dilutions of known concentration are prepared from the protein and assayed alongside the unknown(s) before the concentration of each unknown is determined based on the standard curve.
Two assay procedures are presented. Of these, the Test Tube Procedure requires a larger volume(0.1ml) of protein sample; however, because it uses a sample to working solution ratio of 1:20(v/v), the effect of interfering substances minimized. The Microplate Procedure affords the sample handling ease of a microplate and requires a smaller volume (10-25 ul) of protein sample; however, because the sample to working solution ratio is 1:8 (v/v), it offers less flexibility in overcoming interfering substance concentrations and obtaining low levels of detection.


 
- Colorimetric method; read at 562 nm
- Compatible with most ionic and nonionic detergents
- Faster and easier than the lowry method
- All reagents stable at room temperature for 2 years
- Working solution stable for 24 hours
- Linear working range for BSA: 20-2,000 ug/ml
- Adaptable to microplates
- Less protein-to-protein variation than dye-binding methods


 
* Solution A
250 ㎖x 2 ea
* Solution B
10 ㎖
* BSA solution (2mg/ml)
1 ㎖ x 10 ea
Storage at RT
(If either Solution A or Solution B precipitates upon shipping in cold weather or during long-term storage, dissolve precipitates by gently warming and stirring solution. Discard any kit reagent that shows discoloration or evidence of contamination. )


 
Improved sensitivity & Linear working range
Fig. 1. Comparison of sensitivity of protein assay
SMARTTM BCA Protein Assay Kit (for Standard Assay) shows improved sensitivity higher than competitor product as 15-20%.
The color response was estimated micro well plate reader (37℃/30 minute incubation)
 
HIGH FIDELITY
 
Fig. 2. Typical color response curves for BSA, Chymotrypsin and Lysozyme using the Microplate Protocol.
Absorbance ratios (562 nm) for proteins relative to BSA. The SMARTTM BCA Protein Assay Kit (for Standard Assay) showed higher sensitivity (slope) than Competitor. However, The Protien-to-Protein variations showed similar patters.
A; SMARTTM BCA Protein Assay Kit, B; Competitor A Product